PerkinElmer

Search Results for 'LAMBDA'

Products & Services (242)
Filters:
Product Type
  • Accessories (108)
  • Consumables (98)
  • Instruments (21)
  • Reagents (5)
  • Service Parts (2)
  • Software and Informatics (8)
Automation Compatible
  • Yes (5)
Application
  • Protein Analysis & Detection (5)
Assay Points (200-50,000)
  • 100 (2)
  • 10000 (1)
  • 500 (3)
  • 5000 (2)
Assay Target
  • IFN-λ2 (2)
  • IgM (1)
  • Kappa light chain (2)
Assay Target Class
  • Antibody (3)
  • Cytokine (2)
Depth
  • 12.5 mm (2)
Detection Method
  • Alpha (4)
  • Time-Resolved Fluorescence (TRF) (1)
  • TR-FRET (1)
Experimental Type
  • In vitro (5)
Format
  • Microplates (5)
Inner Diameter
  • 2.06 mm (1)
Material
  • Deuterium (7)
  • PVC (1)
  • Quartz (3)
  • Tungsten (5)
  • Xenon (1)
Minimum Temperature (Celcius)
  • 10-20 (18)
Maximum Temperature (Celcius)
  • 30-40 (18)
Model Compatible With
  • AAnalyst 100 (2)
  • AAnalyst 200 (2)
  • AAnalyst 300 (2)
  • AAnalyst 400 (2)
  • LAMBDA (131)
  • LAMBDA 10 (1)
  • LAMBDA 20 (2)
  • LAMBDA 20 Bio (1)
  • LAMBDA 25 (1)
  • LAMBDA 265 (2)
  • LAMBDA 35 (1)
  • LAMBDA 365 (5)
  • LAMBDA 40 (2)
  • LAMBDA 40 Bio (1)
  • LAMBDA 40P (1)
  • LAMBDA 45 (1)
  • LAMBDA 465 (5)
  • LAMBDA 800 (1)
  • LAMBDA 900 (1)
  • LAMBDA Bio (1)
  • PinAAcle 900 F (2)
Product Brand Name
  • AlphaLISA (4)
  • LAMBDA (18)
  • LANCE Ultra (1)
Product Group
  • Accessory Boards (1)
  • Auto Sippers and Autosamplers (2)
  • Bulbs & Lamps (14)
  • Calibration Materials (6)
  • Cell Changers (6)
  • Cell Holders (10)
  • Cell Holders and Changers (2)
  • Cell Holders and Changers (1)
  • Depolarizers & Accessories (5)
  • Dissolution Manifolds (2)
  • Fiber Optic Accessories (5)
  • Flow Cells (1)
  • GPOB (6)
  • Integrating Spheres (4)
  • Integrating Spheres Supplies (13)
  • PeltierTM Accessories (5)
  • Peltier? Accessories (1)
  • Peristaltic Pump Tubing (1)
  • Peristaltic Pumps (1)
  • Reflectance Accessories (9)
  • Sample Holders & Supplies (28)
  • Sample Holders & Supplies (1)
  • Semi-Micro Cells, Ultra Micro Cells (1)
  • Starter Kit (11)
  • Thermostatting Accessories (7)
  • Transmission Accessories (7)
  • Tubing (1)
  • Tubing Kits and Spares (2)
  • Ultra-Micro Cells (1)
  • UPS System (2)
Style
  • Standard (1)
Technology
  • UV/Visible (15)
Technology Type
  • UV/VIS (138)
  • UV/Visible (UVS) (2)
Therapeutic Area
  • Biologics/Bioprocess (3)
  • Inflammation (2)
Technology
  • UV/Visible (15)
Type
  • Standard Two-Stop (1)
Volume
  • 0-50 (2)
  • 51-100 (1)
  • 151-200 (1)
  • 251-300 (1)
  • 351-400 (1)
Volume Capacity
  • 160 μL (1)
  • 18 μL (1)
  • 30 μL (2)
  • 300 μL (1)
  • 370 μL (1)
  • 390 μL (1)
  • 600 μL (1)
  • 62 μL (1)
  • 8 μL (1)
  • 80 μL (1)

Sort by

1-25 of 242 Products & Services

  • PerkinElmer

    Multi-Cell Peltier? Temperature Control Cover for LAMBDA 465

    The Multi-Cell Peltier?Temperature Control Cover is designed to cover up to 8 cells (8 samples or 7 samples and 1 reference) in the Peltier? Controlled Multi-Cell Holder for LAMBDA 465 (N4101091).
    List Price : 412.00 USD
  • Quartz SUPRASIL- 1mm LP

    UV Quartz SUPRASIL Flow-Through Cell

    Flow-through cells have a center height of 15 mm, two clear windows, two screw connectors (M6 x 1), and come with 500 mm length of FEP tubing (1.9 OD mm, 1.1 mm ID). 1/Pack. UV Quartz SUPRASIL? cells are made from quartz of the highest purity and homogeneity. They have a spectral range of 200 - 2,500 nm and are marked by a blue PerkinElmer logo.

    Price Range : 365.00 USD - 1341.00 USD
  • PerkinElmer

    Fiber Optic Dip Probe for LAMBDA Spectrometers

    The Fiber Optic Dip Probe is a 15 mm, 316-grade stainless steel probe with a wavelength of 200 to 1100 nm. Probe tips must be ordered separately.

    List Price : 2043.00 USD
  • UVWinLab Software for UV/Vis

    UV WinLab Software for Uv/Vis

    UV WinLab is the instrument control and data manipulation software for the latest range of PerkinElmer LAMBDA? 365, 650, 750, 850, 950, 1050.
    List Price : 1682.00 USD
  • PerkinElmer

    Optical Breadboard Base Plate, Sample compartment

    Optional replacement for standard sample floor of LAMBDA 650//750/850/950/1050. Manufactured from stainless steel to help prevent corrosion and to allow the use of magnetic components. Supplied with industry standard hole patterns and thread sizes (1/4-20 tread size on 1” centers). Allows the use of almost unlimited array of holders, mounts or stages from a variety of vendors.
    List Price : 588.00 USD
  • LAMBDA Bio with Printer

    LAMBDA Bio+ with Printer

    For over 50 years we have remained at the forefront of research and innovation. Now, we have drawn on our experience to bring you the LAMBDA Bio+ spectrophotometer, the instrument you can depend on to meet the demands of your busy laboratory.
  • PerkinElmer

    Sample Tilt Option for ARTA

    The Sample Tilt Option for ARTA is an optional sample holder with a motorized tilting stage that allows samples to be analyzed at varying angles of incidence and detection. Automated tilt of up to 75°.
  • PerkinElmer

    16-Channel Peristaltic Pump Set

    The 16-Channel Peristaltic Pump Set is designed to work with dissolution systems. The set includes a 16-channel pump, tygon tubing (2.06 x 0.8), special connectors, cables, and the Accessory Board Kit for the LAMBDA 25/35/45 (L6000500). Requires, but does not include a flow cell.

    List Price : 7600.00 USD
  • PerkinElmer

    Lens Assembly Kit

    The Lens Assembly Kit is an optional General Purpose Optical Bench kit. It allows you to focus a beam on a small spot using several plane convex lenses and iris diaphragms.
  • PerkinElmer

    Flat mirror kit

    Kit consists of two, 2 inch square plane mirrors on magnetic mounts.
  • PerkinElmer

    Film Polarizer for the Double Polarizer Drive

    The Film Polarizer Element works with the Double Polarizer Drive (B0505530). This high performance film polarizer has a wavelength range of 400-700 nm, but other wavelength ranges are availble upon request. It .

    List Price : 733.00 USD
  • PerkinElmer

    Relative Reflectance Accessory

    For reflectance of thickness measurements 80° of light incidence.
  • PerkinElmer

    Absolute Directional VW Specular Reflectance Accessory

    A Unique Accessory The VW directional reflectance accessory is the only commercially available accessory that can perform absolute reflectance measurements at oblique as well as near-normal incidence at an accuracy level comparable with that of National Metrology laboratories. This tool, when combined with the Lambda 800 UV/Visor the Lambda 900 UV/Vis/NIR spectrometer, provides superior data quality with sampling flexibility.
  • 8-Position Multicell Holder for LAMBDA 365

    8-Position Multicell Holder for LAMBDA 365

    Accommodates any standard 10 mm cells; up to 8 samples.
  • PerkinElmer

    Cell Changer for High Performance LAMBDAs

    The HP LAMBDA Linear Cell Changer transports sample and reference positions for the high performance LAMBDA spectrometers. Cell holders are required, but not included. Your choice of recommended cell holders (2 of each) are the 5-Position Long Pathlength cell holder (B0089439) or the 8-Position, Water-Thermostattable cell holder (B2205411).

    List Price : 4088.00 USD
  • PerkinElmer

    Multi-Purpose Silicone Tubing

    Multi-purpose Silicone Tubing is compatible with the LAMBDA 850/950 spectrometers. It is 1m in length with an outer diameter of 4 mm and an inner diameter of 1.5 mm.
    List Price : 11.00 USD
  • LANCE Detection Kit

    Kappa Light Chain (human) LANCE Ultra TR-FRET Detection Kit

    The LANCE? Ultra Human Kappa Light Chain Detection Kit is designed for detection and quantitation of human kappa light chain in buffered solution and cell culture media using a homogeneous TR-FRET (no-wash steps, no separation steps) assay.
    Price Range : 969.00 USD - 12900.00 USD
  • PerkinElmer

    8+1 Position Dissolution On-line Kit

    The 8+1 Position Dissolution On-line Kit is compatible with the LAMBDA 25 spectrometer. It includes the Linear Transport cell changer (B2000186), an auxiliary Single Reference Cell holder (B2000201), the Water-Thermostattable 8-Cell holder (B2205411), the Dissolution Manifold (B0196887) and the necessary tubing and adapters. This kit requires, but does not include, a flowcell.
    List Price : 6300.00 USD
  • PerkinElmer

    LAMBDA 25 Ultra-Micro Cell Enhanced Kit with Reference Material

    Contains additional high-precision quartz and glass 10 mm cells for routine liquids work and replacement deuterium and tungsten lamps to ensure maximum instrument uptime.
    List Price : 3565.00 USD
  • PerkinElmer

    LAMBDA 25 Ultra-Micro Cell Premium Kit with Sipper

    Contains additional high-precision quartz and glass 10 mm cells for routine liquids work and replacement deuterium and tungsten lamps to ensure maximum instrument uptime.
    List Price : 5500.00 USD
  • UVWinLab1

    Protection Glass Software with UV WinLab

    A dedicated software package offering industry standard calculations required for personal and industrial eye protection. Included are luminous, visible, UV and near-IR transmittance calculations along with shade number and relative visual attenuation. UV WinLab is the instrument control and data manipulation software for the latest range of PerkinElmer LAMBDA? 365, 650, 750, 850+ and 1050+ spectrometers.
    List Price : 1008.00 USD
  • PerkinElmer

    16-Cell Dissolution Manifold

    The 16-Cell Dissolution Manifold is a replacement front manifold plate for the LAMBDA 25/35/45. It accommodates the inlet and outlet tubes necessary for dissolution analysis. This accessory includes internal hoses that connect the flowcells to the manifold, and sheathed flexible cables that connect the manifold to a peristaltic pump.

    List Price : 2818.00 USD
  • PerkinElmer
    List Price : 130.00 USD
  • Test Tube Holder for LAMBDA Spectrometers

    This holder accommodates test tubes, vials, ampules, and cylinder type cuvettes from 11 to 17 mm in diameter.
    List Price : 941.00 USD
  • Universal Reflectance Accessory (URA) - UV/Vis

    This Universal Reflectance Accessory (URA) - UV/Vis is compatible with LAMBDA 650/850/850+ spectrometers. PerkinElmers's unique Universal Reflectance Accessory (URA) is the only fully-automated, multi-angle, absolute specular reflectance accessory available today. Simply place the sample on the horizontal sample plate, select the required measurment angles, and scan.

  • Jump to:
Business Insights (25)
Filters:
Resource Library
  • Application Note (21)
  • Poster (1)
  • Technical Note (1)
  • White Paper (2)

Sort by

1-25 of 25 Business Insights

  • White Paper

    Data Integrity - UV WinLab Enhanced Security (ES) Software for UV/Visible Spectroscopy

    The FDA defines data integrity as "completeness, consistency, and accuracy of data. Complete, consistent, and accurate data should be attributable, legible, contemporaneously recorded, original or a true copy, and accurate (ALCOA)". ALCOA itself has evolved to ALCOA Plus, which incorporates two of the fundamental definition terms as stated by the FDA; complete, consistent, enduring, and available. Compliance with 21 CFR Part 11 is mandatory for pharmaceutical companies and their suppliers to sell products into the United States, and also applies to other related industries.

    PerkinElmer's UV WinLab? Enhanced Security (ES) software platform for UV/Visible spectroscopy provides structural requirements and features to assist with the needs for ensuring data integrity and compliance. It affords the system owner the ability to comply with regulations and incorporate features into the validation plan to exhibit compliance. The purpose of this document is to demonstrate how UV WinLab ES meets the technical requirements for 21 CFR Part 11.

  • Application Note

    Water Analysis using LAMBDA Spectrophotometer: Nitrate Nitrogen (NO3-N), Brucine Method

    When a water sample containing nitrate ions is treated with brucine in sulfuric acid condition, a yellow compound is created. The quantity of nitrate nitrogen can be determined by measuring the absorbance of the yellow compound at 410 nm. In this application note, the quantitative analysis of Nitrate nitrogen (NO3-N) was performed by Brucine method. Data was rapidly acquired using the LAMBDA? 465 UV/Vis Spectrophotometer and processed using the UV Lab? Software.

  • Application Note

    Water Analysis Using LAMBDA UV/Visible Spectrophotometers: Ortho-Phosphate Determination

    In surface waters, phosphorus commonly exists in its phosphate form. A high concentration of phosphate in water is indicative of domestic waste, industrial effluent, and agricultural runoff which can lead to eutrophication. Eutrophication causes an increase in plant and algal growth, which decreases the dissolved oxygen in the water, often leaving the water uninhabitable to organisms. In this application, the quantitative analysis of ortho-phosphate was performed using the LAMBDA 265 UV/Vis spectrophotometer and CHEMetrics ortho-phosphate cell test kit.

  • Application Note

    Water Analysis Using LAMBDA UV-Visible Spectrophotometers: Nitrate-Nitrogen Determination

    Nitrate ions react with 2,6-dimethyl phenol (DMP) in sulfuric and phosphoric solution to form 2,6-dimethyl-4-nitrophenol (Figure 2) which can be detected spectrophotometrically at 340 nm and is directly proportional to the nitrate-nitrogen concentration. The Merck test kit allows the concentration to be determined without the use of a calibration curve by multiplying the measured absorbance at 340 nm by a known factor. In this application, the quantitative analysis of nitrate was performed using the LAMBDATM 265UV-Vis spectrophotometer and Merck Spectroquant? cell test. The method used is analogous to DIN 38405-9.

  • Application Note

    Pharmaceutical Assay and Multicomponent Analysis using the LAMBDA 365 UV/Vis Spectrophotometer

    Combination drugs containing Paracetamol and Aspirin are widely used analgesics with anti-inflammatory properties for treatment of migraines. UV/Vis spectrometry is a fast and commonly used technique in quality control laboratories for routine analysis of purity and quantity of components within various stages of a product’s manufacture in many industries. This application describes the efficient use of the LAMBDA 365? UV/Vis spectrometer in determining the quantity and percent assay of Paracetamol according to U.S. Pharmacopeia’s (USP) methods, and component concentration in pharmaceutical formulations, while achieving 21 CFR Part 11 compliance.

  • Application Note

    The Quantification of Oligonucleotide Using a LAMBDA 465 UV/Vis Spectrophotometer

    Using the LAMBDA 465 UV/Vis Spectrophotometer and UV Lab software, quantification of the oligonucleotide was performed.The range of concentrations was 0.5 - 2.0 μM. Rapid acquirement of spectra and good sensitivity were obtained with the LAMBDA 465.

  • White Paper

    Weighing the Benefits and Risks of Nanotechnology White Paper

    There is a growing body of evidence showing that there are significant differences between some nanomaterials and their non-nanoscale counterparts. What those differences portend raises many new questions about their potential to cause harm to human health and the environment.

  • Application Note

    The Determination of Total Protein Using the LAMBDA UV/Vis Spectrophotometer: Bradford Method

    Quantification methods for total protein are among the longest-established fundamental and important experiments of bioscience. UV/Vis Spectrophotometry is widely used for the determination of protein. This application note describes a typical protein method, the Bradford method. Data is rapidly acquired using the LAMBDA? 465 UV/Vis Spectrophotometer and processed using the UV Lab Software.

  • Application Note

    Water Analysis Using LAMBDA UV/Visible Spectrophotometers: Iron Determination

    Iron is rarely found in its elemental form in nature due to the high tendency of its ions, Fe(II) and Fe(III), to form oxygen and sulphur containing compounds. Concentrations of iron found in surface waters are typically no greater than 1 mg/L, unless contaminated by industrial effluents, whilst much higher concentrations are found in ground waters. The World Health Organization guideline for iron in drinking water is 0.3 mg/L as undesirable bacteria growth in water systems occurs above this concentration. In this application, the quantitative analysis of iron was performed using the LAMBDA 265? UV/Vis spectrophotometer and CHEMetrics iron cell test kit.

  • Application Note

    Water Analysis using LAMBDA: Total Phosphorus (T-P), Ascorbic Acid Method

    Principle Total phosphoric compounds in water sample is changed to phosphate (PO4 -) form by oxidation. After treatment with ammonium molybdate ? ascorbic acid solution, blue color is created. This color is measured at 880 nm. In this application note, the quantitative analysis of total phosphorus (T-P) was performed by as-corbic acid method. Data are rapidly acquired using LAMBDA? 465 UV-Vis Spectrophotometer and processed using UV Lab? Software.

  • Poster

    Functional Measurement in Nanomaterials using Optical and Thermal Techniques

    Advanced instrumentation is key to work in nano-materials. Functional tools such as optical and thermal measurement techniques allow the characterization of materials. As such, they complement imaging tools such as AFM and TEM-SEM which give spatial information on the structure of the materials. This poster presents examples of recent challenging measurements carried out in band gap analysis, plasmon resonance and polymorphic structure.

  • Application Note

    Determination of Cholesterol Level in Human Serum - Enzymatic Colorimetric Method

    Clinical chemistry uses chemical processes to measure levels of chemical components in the blood. It is very useful for the early diagnostic of disease and for monitoring organ function. The most common specimens used in clinical chemistry are blood and urine and this application note shows the common blood tests and measurable items using UV/Vis spectrophotometers as determined by the enzymatic method.

  • Application Note

    Measurement of Gold Nanoparticle Solutions on the LAMBDA 265

    The data shows the suitability of the LAMBDA 265 for producing rapid, high-quality spectra. It also shows that the instrument is able to measure the higher nanoparticle sizes, even though these scatter light to a greater extent due to the increased particle size and also settle out more quickly.

  • Application Note

    Water Analysis Using LAMBDA UV/Visible Spectrophotometers: Ammonia-Nitrogen Determination

    Ammonia-nitrogen (NH3-N) occurs naturally in groundwaters at concentrations below 0.2 mg/L and up to 12 mg/L in surface waters, as a result of decomposition of organic matter. High concentrations of ammonia in surface waters are toxic to aquatic life and are indicative of contamination from industrial effluent, raw sewage and agricultural runoff. Ultimately the pH value of the water determines whether ammonia-nitrogen is found as NH4+, NH4OH or NH3. 1 In this application, the quantitative analysis of ammonia-nitrogen was performed using the LAMBDA 265? UV/Vis spectrophotometer and CHEMetrics ammonia nitrogen cell test.

  • Application Note

    Spectral Transmission of Pharmaceutical Containers in Accordance with USP <671>

    All medicinal products need to be protected and packaged in containers which conform to prescribed standards. The quality of pharmaceutical packaging can have a significant impact on the performance of pharmaceutical products and can reduce shelf-life if the improper packaging is used. The USP chapter, <671>, “Containers – Performance Testing” provides standards for the functional properties of packaging systems used for solid and liquid oral dosage forms for pharmaceuticals and dietary supplements. This application note demonstrates the determination of spectral transmission of plastic pharmaceutical containers using the PerkinElmer LAMBDA? 1050+ UV/Vis/NIR spectrophotometer, in accordance with USP <671>.

  • Application Note

    Monitoring Fast Chemical Reactions Application Note

    Spectrosopic techniques, such as UV-Visible spectrometry, can be deployed to observe the chemical changes taking place during fast reactions. However, in many cases the reaction timescales are too fast to be performed and observed by the simple manual mixing of the reactants in a cuvette. The stopped-flow technique is frequently used for rapid kinetics experiments allowing the reactants to mix effectively and react whilst monitoring the reaction in a low volume cuvette in the UV-Visible instrument. This application note demonstrates how the PerkinElmer LAMBDA 465 Diode Array UV-Visible Spectrophotometer together with the TgK Scientific SFA-20 Rapid Kinetics Accessory allows reaction monitoring on the millisecond timescale.

  • Application Note

    Simple Method of Measuring the Band Gap Energy Value of TiO2 in the Powder Form using a UV/Vis/NIR Spectrometer

    The measurement of the band gap of materials is important in the semiconductor, nanomaterial and solar industries. This note demonstrates how the band gap of a material can be determined from its UV absorption spectrum.

  • Application Note

    Gaining high resolution measurements of optical filters in the NIR range with the LAMBDA 1050 UV/Vis/NIR

    Optical filters have many functions, including color correction, used to improve color balance in many optical systems, to neutral density filters that produce specific reduction in the level of transmitted light. The characterization of these diverse optical filter types is critical from design through manufacturing, providing validation of a specific design and the necessary means to perform QC/QA of finished products. This application note highlights PerkinElmer? LAMBDA? 1050 for determining the best method for the analysis of specific optical filters.

  • Application Note

    Water Analysis Using LAMBDA UV-Visible Spectrophotometers: Chemical Oxygen Demand Determination

    Chemical Oxygen Demand (COD) is used as an indirect measurement of the sum of oxidizable matter in water and measures the equivalent amount of oxygen required to oxidize organic compounds. Wastewater commonly contains organic compounds, as a result of industrial processes, which can oxidise in the presence of dissolved oxygen in the water. Low levels of dissolved oxygen can be detrimental to aquatic life but high levels may cause corrosion of metal pipes. It is important to use COD as an indicator of water quality. In this application, quantitative analysis of COD was performed using the LAMBDA 265TM UV-Vis spectrophotometer and Merck Spectroquant? COD mercury free cell test.

  • Application Note

    Measuring Absorptance (k) and Refractive Index (n) of Thin Films with the PerkinElmer LAMBDA 1050+ High Performance UV/Vis/NIR SpectrometersUV/Vis Spectroscopy

    An optical coating consists of a combination of thin film layers that create interference effects used to enhance transmission or reflection properties for an optical system. How well an optical coating performs is dependent upon the number of factors, including the number of layers, the thickness of each layer and the differences in refractive index at the layer interfaces. The transmission properties of light are predicted by wave theory. One outcome of the wave properties of light is that waves exhibit interference effects. Light waves that are in phase with each other undergo constructive interference, and their amplitudes are additive. Light waves exactly out of phase with each other (by 180°) undergo destructive interference, and their amplitudes cancel. It is through the principle of optical interference that thin film coatings control the reflection and transmission of light.

  • Application Note

    High Absorbance Scanning with the PerkinElmer LAMBDA 850 UV/Vis and LAMBDA 950/1050 UV/Vis/NIR Spectrophotometers

    In materials research there is sometimes a need to scan high absorbance samples such as laser protection lenses, optical filters, and polarization materials. Such sample types often need to be measured across the whole UV, Vis and NIR ranges of the electromagnetic spectrum.

  • Application Note

    Water Analysis Using LAMBDA UV-Visible Spectrophotometers: Nitrite Determination

    Nitrite, occurs naturally in the environment as an intermediate of the nitrogen cycle through microbial decomposition of organic matter. However, nitrite contains nitrogen in a reasonably unstable oxidation state and readily oxidizes to nitrate. As a result, nitrite is present at considerably lower concentrations in ground and surface waters than nitrate1. Higher concentrations of nitrite are indicative of pollution by industrial wastewater or agricultural run-off. In this application, the quantitative analysis of nitrite-nitrogen was performed using the LAMBDA? 265 UV-Vis spectrophotometer and CHEMetrics nitrite test kit.

  • Application Note

    Water Analysis Using LAMBDA UV/Visible Spectrophotometers Hexavalent Chromium Determination

    Chromium (VI) ions react with diphenylcarbazide in weakly phosphoric solution. The product, diphenylcarbazone, is a red-violet complex which can be detected photometrically at 550 nm. The chromate cell test kit is suitable for the concentration range of 0.11 – 4.46 mg/L chromate allowing the concentration of chromium(VI) in a water sample to be determined without the use of a calibration curve by multiplying the measured absorbance at 550 nm with a known factor.

  • Technical Note

    Full-Spectrum, Angle-Resolved Reflectance and Transmittance of Optical Coatings Using the LAMBDA 1050+ UV/VIS/NIR Spectrophotometer with the ARTA Accessory

    We evaluated a 3M? visible mirror film for potential use in a new curved photovoltaic module using a LAMBDA 950 spectrophotometer with an ARTA accessory. In this application, the 3M? film must transmit near-infrared photons to the underlying silicon solar cells (where they will be converted directly to electricity) while reflecting visible photons to the focus of the module where they may be absorbed by, for example a wavelength-agnostic thermal absorber used to drive a heat engine.

  • Application Note

    Water Analysis Using LAMBDA UV/Visible Spectrophotometers: Formaldehyde Determination

    In this application, the quantitative analysis of formaldehyde was successfully executed using the LAMBDA 265 UV/Vis spectrophotometer and Merck Spectroquant formaldehyde cell test kit. Principle Formaldehyde reacts with chromotropic acid in sulphuric solution to form a violet dye which can be detected photometrically at 565 nm. The formaldehyde cell test kit is appropriate for the concentration range of 0.10 to 8.00 mg/L formaldehyde allowing the concentration of formaldehyde in a water sample to be determined without the use of a calibration curve by multiplying the measured absorbance at 565 nm by a known factor.

刷流水赚钱平台